HV Diagnostix S453 Microhmmeter 100A/220A

$5,295.00 Excl. GST

S453 Microhmmeter

Features

  • High resolution: 0.01 μΩ
  • Wide current measurement range: 5A to 220A
  • Standard resistor for accuracy test
  • Handheld, rugged, easy-to-operate
  • High stability with open circuit and overheating protection
  • Bluetooth connection for instrument control, data storage/export, real-time viewing
  • Computer software: supports exporting data, recording test data per second, and controlling instrument testing

HV Diagnostix S453 Microhmmeter 100A/220A

$5,295.00 Excl. GST

In stock

Description

Specifications

  • Function: Contact resistance tests of high-voltage switches and circuit breakers; connection resistance tests of metallic welding components; circuit resistance tests of conductors; precise low resistance tests
  • Power: Built-in 12.6V 9000mAh rechargeable lithium battery
  • Measurement Method: 4-wire measurement
  • Charger: 12.6V/2A
  • Display: 5.6-inch industrial LCD with high-brightness color
  • Test Interface: I+, I-, U+, U-
  • Resolution: 0.01 μΩ
  • Printer: Optional, press print button to print results

Measurement Range

  • ≤5A: 1 μΩ to 3500 mΩ
  • 10A: 0.1 μΩ to 200 mΩ
  • 30A: 0.1 μΩ to 20 mΩ
  • 50A: 0.01 μΩ to 15 mΩ
  • 80A: 0.01 μΩ to 10 mΩ
  • 100A: 0.01 μΩ to 5 mΩ
  • 200A: 0.01 μΩ to 600 μΩ
  • 220A: 0.01 μΩ to 500 μΩ

Output Current

  • ≤5A, 10A, 30A, 50A, 80A, 100A, 200A, 220A
  • Step current: 2.5A, up to 59 current gears

Accuracy

  • 30A to 220A: 0.01 μΩ to 20 mΩ → 0.5% ± 1 μΩ
  • 5A to 10A: 0.1 μΩ to 200 mΩ → 1% ± 5 dgt
  • ≤5A: 1 μΩ to 3.5 Ω → 1% ± 5 dgt

Data Storage

  • Automatically and cyclically saved after test
  • Up to 999 sets of data

Physical Details

  • Instrument size: L188mm × W85mm × H312mm
  • Outer package size: approx. L550mm × W420mm × H215mm
  • Weight: Instrument approx. 2.2 kg; Total approx. 9.3 kg
  • Test leads: Standard length 3m (optional 5m)

Other Features

  • Backlight: High, medium, low brightness
  • Circuit protection: Open circuit, overheat protection
  • Temperature protection: By temperature monitoring
  • Charging voltage: 12.6V
  • Working temperature: –10°C to 50°C; below 90% RH, no condensation
  • Storage temperature: –10°C to 60°C; below 70% RH
  • Data export: Bluetooth connection, Android App to export Excel files
  • Computer software: Export test data, record continuously, display real-time data, control instrument
  • Auto shut-down: Battery shuts down after 15 minutes of inactivity
  • Battery indicator: Displays when power is exhausted
  • Cloud service: Android App, Bluetooth connection; upload pictures and data, generate reports and graphs, share equipment, view data simultaneously
  • Safety standards: IEC61010-1, IEC61326-1; IEC61000-3-2; CAT III 600V, Pollution Level 2; DL/T967-2005