Flow Analyser PF-300
Premium bench-top ventilator tester for engineers and health care professionals.
Test, verify and calibrate any kind of medical device that exerts pressure or produces flow such as ventilators, respirators and anaesthesia machines.
The FlowAnalyser measures bi-directionally flow, various pressures, temperature, humidity and O2 concentrations. The unique measuring modes for adult, pediatric and high frequency ventilators accelerates test duration significantly. It incorporates remote control interface, data storage, internal battery and the high end PC-based Software tool FlowLab.
Download Technical Specifications
FLUIDS/ Archimedes Principle Experiment, EX-9909
The complete solution for exploring the dependence of the buoyant force on density, mass, and volume.
WHAT'S INCLUDED
- 1x Density Set (ME-8569A)
- 1x Overflow Can (SE-8568)
- 1x Large Rod Base (ME-8735)
- 1x 45 cm Stainless Steel Rod (ME-8736)
- 1x Braided Physics String (SE-8050)
- 1x Ohaus Triple-Beam Balance (with Tare) (SE-8707)
- 1x Stainless Steel Calipers (SF-8711)
- 1x 1000 ml Beaker
- 1x 100 ml Beaker
- 1x 50 ml Graduated Cylinder
- 1x Archimedes’ Principle Experiment Manual
FLUIDS/ Piping Systems, EX-5553
In this experiment, students determine the major losses due to friction in pipes and the minor losses due to elbows and valves.
WHAT'S INCLUDED
- 1x General Flow Sensor
- 1x Venturi Tube
- 1x PASPORT Dual Pressure Sensor
- 10x Pressure Taps (set of 6)
- 1x Water Pump
WHAT TO CONSIDER
See the Buying Guide for this item's required, recommended, and additional accessories.
FLUIDS/ Pumping Systems, EX-5554
In this experiment, students determine the characteristic curves for two pumps and examine the impact of placing pumps in series and in parallel.
WHAT'S INCLUDED
- 1x General Flow Sensor
- 1x Venturi Tube
- 1x PASPORT Dual Pressure Sensor
- 10x Pressure Taps (set of 6)
- 2x Water Pump
WHAT TO CONSIDER
See the Buying Guide for this item's required, recommended, and additional accessories.
Forces and Motion Kit, EP-3576
Perform lab activities from the Comprehensive Physics Investigations Lab Manual.
WHAT'S INCLUDED
See the Product Description for this item's included accessories.
WHAT TO CONSIDER
See the Buying Guide for this item's required, recommended, and additional accessories.
Frankonia ABSORBING CLAMP - ACF-01B
acc. to CISPR-16-1-3, EN 55014-1
Technical data
- Frequency range: 30 MHz to 1000 MHz
- Typical insertion loss acc. to CISPR-16: 17 dB ±4 dB
- Decoupling (typ.): 1 MHz -30MHz: 5dB – 20dB, >20dB from 30MHz to 1 GHz
- Impedance: 50 Ω
- Max. input current (peak): 30 A
- Input power (peak): 5 W
- Max. cable diameter: 20mm
- Dimensions (B x H x D) in mm: 600 x 105 x 80
- Weight: 6.5kg
EMI power dBpW = Measured Voltage dBµV + (Correction Clamp dB incl. optional Attenuator)
Frankonia ACTIVE LOOP ANTENNA – LAX-10
9 kHz – 30 MHz,  for H-field measurements
Application
The active loop antenna LAX-10 can be used for the frequency selective measurement of magnetic fields in the long wave, mid wave and short wave frequency ranges. It can be used for testing according to CISPR, MIL, FCC, EN, ISO, ANSI, ETSI and many other standards.
Frankonia AVTC
Automotive Component and Vehicle Testing Chamber
The AVTC is Frankonia’s automotive anechoic chamber solution at typical 3,0m measuring distance offering a typical Quiet Zone (QZ) of ø3,0m. It is adapted for radiated emissions and immunity tests on vehicles and components as well as for commercial product tests. The AVTC-L is the extended version of Frankonia’s automotive anechoic chamber solution at 3,0m and 5,0m measuring distance. The AVTC-XL offer the integration of a normal range dynamometer.
Frankonia BROADBAND ANTENNA ALX-4000 / ALX-4000E / ALX-8000E
The ALX-4000E is an especially optimized version for emission measurements. It offers lower antenna factors and improved VSWR. Additionally it can be used for immunity tests which require an input power of less than 100 W cw (200W intermitt.).
The ALX-8000E has an extended frequency range up to 8 GHz. All antennas are supplied with antenna factors for 3.0 m and 10.0 m measuring distance (1.0 m on request).
Frankonia BROADBAND HORN ANTENNA – HAX-18
800 MHz – 18 GHz
For immunity tests and emission measurements
Frankonia BROADBAND HORN ANTENNA – HAX-6
500 MHz – 6 GHz
For immunity tests and emission measurements
Frankonia BROADBAND HORN ANTENNA – HAX-6-KFZ
800 MHz – 6.2 GHz