Laplace EMC Analyzers SA3000/SA1002
Apart from the maximum frequency, these analyzers are identical. Both analyzers are available with a band A option to cover the range 9KHz-150KHz.
They offer the ability to perform pre-compliance testing and compliance measurements. If measuring conducted emissions, use of a pre-selector is recommended owing to the impulsive nature of conducted signals. These analyzers are supplied complete with PC software, fully compatible with Windows versions from XP to Win10.
Data Sheet SA1002 EMC Analyzer
Data Sheet SA3000 EMC Analyzer
Laplace EMISSIONS REFERENCE SOURCE
Reference Sources
Reference sources are compact signal sources that facilitate the calibration of EMC test equipment.
The Radiated source (ERS) will check both the site and the measurement equipment. This is particularly important as the greatest source of measurement uncertainty is invariably the site.
Laplace Harmonics & Flicker Analyzer AC2000-A
The Laplace Harmonics and Flicker analyser provides the user with a complete system for testing product compliance with IEC61000-3-2 and IEC61000-3-3. Quick and easy to use, the built-in screen provides a clear pass/fail indication of compliance status, plus a full listing of results for each harmonic, in either tabular of bargraph format. The instrument is properly configured to cope with fluctuating harmonics. The Flicker mode provides proper measurement of short term and long term parameters, using algorithms specified in IEC61000-4-15. In addition, inrush current measurements can be automated such that the product under test can be automatically cycled on/off with user entered time profiles.
Laplace Pre-selectors RF910/RF915
These Pre-Selectors are high specification, switched band filters which track the scanning of the EMC Analyzer. Control is via USB link from the Laplace EMC Engineer software supplied with SA1002 and SA3000 analyzers. Installation and operation is completely automatic, and the filters will synchronize with the analyzer scan without any operator intervention. A front panel switch allows manual operation if required.
Two models are available:
RF910 Band B, 150KHz - 30MHz. 8 filter bands
RF915 Band A & B, 9KHz - 30MHz. 13 filter bands
Pass band attenuation is just 4dB and out-of-band rejection is nominally 40dB.
Laplace Synthesizer RFIC-4-6
The Laplace Synthesisers cover both conducted and radiated RF immunity test requirements. The frequency coverage extends from 100KHz to 230MHz for conducted tests (RFIC-4-6) and 30MHz – 6GHz for radiated tests (RF3000/RF6000). They are all controlled from the users PC via a USB link, and powerful Windows software is included to enable the user to control all the parameters of the test, to monitor the test in progress, and to view the results.
RFIC-4-6 is compliance with IEC61000-4-6
Laplace Van Veen Loop RF300
Large Loop Antenna RF300
For EMC Emissions Testing of Luminaires according to EN 55015
- Â Fully compliant with CISPR15
- Â Complete 3 axis design.
-  Fully calibrated, 9KHz—30MHz.
- Â Simple to erect..
- Â Affordable - low cost.
- Â Compatible with any EMC receiver or analyzer.











